Industries

Power centers for data centers and digital infrastructure

Power supply for data centers, server rooms, telecom facilities, and critical digital infrastructure.

For digital infrastructure, key parameters are power availability and predictable cooling. The power scheme is built around continuity and the ability to scale capacity in line with IT load growth.

Facility Challenges

  • — Uninterrupted power supply for IT loads
  • — Power source redundancy
  • — Provision of cooling for machine rooms
  • — Phased power scaling according to site development stages
  • — Peak load management

4DA Energy Solutions Ltd. Solutions

  • — Own generation with parallel operation to the grid
  • — UPS and energy storage in the guaranteed power supply scheme
  • — Backup generation and automatic transfer switch (ATS)
  • — Trigeneration for refrigeration load coverage
  • — Monitoring and dispatching of the energy center

Possible System Configurations

  • — N+1 redundancy for critical loads
  • — Modular energy center with phased power ramp-up
  • — Combination of UPS, energy storage, and generation
  • — Containerized solution for rapid power deployment

Reliability and Redundancy

  • — Load classification by allowable interruption time
  • — Scheduled testing of backup power sources
  • — Automatic transition to island mode
  • — Availability control based on agreed indicators

Integration with Existing Infrastructure

  • — Connection to existing switchgear
  • — Integration with site monitoring systems
  • — Coordination with the cooling system

Service throughout the entire lifecycle

  • — 24/7 monitoring of equipment status
  • — Scheduled maintenance without disrupting site operations
  • — Stock of critical spare parts

Implementation

How the Project is Implemented

Unified 4DA Energy Solutions Ltd. Workflow from Initial Data to Power Plant Operation.

01

Initial Data Collection

Electrical and thermal load profile, available gas resource, connection points, reliability requirements, and facility site.

02

Preliminary Study

Technical feasibility verification: gas balance, operating modes, grid constraints, and preliminary power plant configuration.

03

Technical Concept

Facility energy balance, composition of main and auxiliary equipment, thermal scheme, layout, and CAPEX/OPEX estimation.

04

Financial Model

Power supply economics, transaction structure, and selection of implementation model — EPC, EPC-M, or EPC-F.

05

Contracting

Agreement on scope of work, schedule, guaranteed performance indicators, and risk allocation among project participants.

06

EPC and Commissioning

Design, procurement, construction and installation works, commissioning, and bringing the power plant to design performance.

07

Operation and Maintenance (O&M)

Scheduled maintenance, spare parts, operational mode management, and availability reporting throughout the service life.